TELECOMMUNICATION CABLES

Communication cables for local networks


«back

СВТ

A-2Y(L)2Y

Standard: VDE 0816-1

Description:

PE insulation • unit stranding • laminated sheath

Application:

These cables are used as connecting cables in local networks and in PABX’s for telephone purposes and for the transmission of signals.
They are suitable for underground installation, in cable ducts and conduit, as well as for interior installations.
The use of these cables for power installations is not permitted. These cables may only be used in locations with fire and explosion hazards in conjunction with the appropriate safety precautions.

Characteristics:


Color coding
Number
of quads
Side-circuit - 1 Side-circuit - 2
a-wire b-wire a-wire b-wire
1 white red green blue
2 yellow red green blue
3 gray red green blue
4 brown red green blue
5 black red green blue

Cable construction

Technical data

Conductor Bare copper conductor diameter
0.4 mm , 0.5mm, 0.6mm, 0.7mm
Conductor diameter 0.4 0.5mm
Conductor resistance at 20° C-max 150 95Ω/km
Insulation: PE low density Conductor diameter 0.6 0.7mm
Quad each 4 wires are twisted to a quad Conductor resistance at 20° C-max. 65 49Ω/km
Units 5 quads laid up to a basic unit Insulation resistance -min. 10GΩ.km
Cable core  the units are stranded into a compact cable Mutual capacitance at 800Hz-max. 48nF/km
Unit marking in each layer there is a unit with red supporting spiral from which the counting starts and a unit showing the direction of counting - with yellow supporting spiral Capacitance unbalances at 800Hz:
K1 100% of all values
95% of all values
K9-K12 100% of all values
90% of all values


980pF/500m
420pF/500m
800pF/500m
200pF/m
Wrapping several layers of plastic tapes Test voltage 50Hz, 2 min.
wire - wire
wire - screen


500V
2000V
Screen of aluminum tape , thickness not less than 0.04mm, one side coated with copolymer and 1 tinned copper wire with diameter 0.5mm under the metal foil. Operating voltage peak value
cables with cores 0.4 and 0.5mm
cables with cores 0.6 and 0.7mm


150V
220V
Sheath of PE compound, low density with 2.5% carbon black Temperature range
mobile
fixed

-10° C to +60° C
-50° C to +60° C
Minimum bending radius approx. 10 x cable diameter

Type codes
A           outdoor cable
2Y         polyethylene (PE) insulation
(L)2Y    laminated sheath
StIII     star quad in local cables
Bd        unit type stranding

Cable core construction
Number
of
pairs
Number
of
quads
Number of units
5х4 25х4 50x4

1-st layer

2-nd layer

1-st layer

2-nd layer

1-st layer

2-nd layer

6 3 3-quads.          
10 5 1          
20 10 2          
30 15 3          
50 25 5          
70 35 1 6        
100 50 3 7        
150 75     3      
200 100     4      
250 125     5      
300 150     1 5    
400 200         4  
500 250         5  
600 300         1 5
700 350         1 6
800 400         1 7
1000 500         3 7
1200 600         4 8

 Construction data A-2Y(L)2Y...x2x0.4(0.5, 0.6, 0.7) St III Bd