Standart: NF C 33-209 (HD 626 S1/A2: 2002 – 4E and 6E)

Description: Al conductors • XLPE insulation

Application:

The power cables with cross-linked polyethylene (XLPE) insulation for overhead lines are designed for electrical installations with alternating power networks with nominal voltage Uo/U 0.6/1 kV or in direct power networks with maximum voltage according to land 0.9 кV. The cables with supporting (bearing) zero conductors are used for building networks in city and urban areas and the self-supporting type cables are for building distribution networks in these areas. Cables for overhead installations may be used in different types of installations: on free hanging facades; between posts; on fixed facades; trees and poles. Interception of forest areas without the need of clearance and maintenance of openings is allowed.     -Cables with supporting zero conductor, the whole bundle is suspended and carried by the supporting conductor, which is made of aluminum compound.     - Self-supporting construction, suspension and carrying of the whole bundle is done by the phase insulated conductors. Bundles can include one or two additional conductors for public lighting and control pair.

Features:

 

 

Cable construction

Technical data

Construction According to NF C 33-209 Conductor resistance at 20° C According to NF C 33-209
Operating temperature 90° C continuous operation
Conductor
-phase(main) М
-neutral (supporting) N
-additional for lighting R
Al stranded compacted or Non-compacted according to NF C 33-209
AL stranded according to NF C 33-209
Al stranded compacted or non-compacted according to NF C 33-209

Overload temperature

130° C /100h/per year мах./
Short circuit temperature 250° C /5 s max./
Nominal voltage
АС
DC

Uo/U 0.6/1 kV
0.9 kV
Insulation

XLPE compaund

Highest system voltage AC, not more tha 1.2 kV
Test voltage:
АC -15 min
DC - 15 min
4 kV
10 kV
Color black Bending radius, min 18x D cable
Temperature of laying no less than - 10° C recommended 15 ° C
Marking raised with paint:
- phase ( М ) – with numbers 1;2;3
- supporting 0 core( N )
ELKABEL NF C 33-209 additional cores for lighting ( R ) - EP1 and EP2
Resistance at 20° C: 16 - 1.91 Ω/км 70 - 0.443Ω/km
25 - 1.20 Ω/км 95 - 0.320Ω/km
35 - 0.868Ω/км 120 - 0.253Ω/km
50 - 0.641Ω/км 150 - 0.206Ω/km
54.6Alm - 0.63Ω/км;70Alm- 0.5Ω/km; 95Alm - 0.343Ω/km
Supported neutral breaking strength min. for 54.6 - 16.6кN
for 70 - 20.50kN
for 95 - 27.50кN